unconfigured good

相關問題 & 資訊整理

unconfigured good

It could look like this in the Event Viewer. User-added image. And like this in the MegaRaid Storage Manager User-added image. Go back to the ISIS 5000 management console and follow the following. User-added image. 1. Click Storage Managemers 2. Click th,Changing the status of the new drive from Unconfigured to Online. , A drive in the QRadar appliance that was replaced, is not automatically rebuilt into the RAID array, and is reported as "Unconfigured (good)"., 針對當時的狀況, 視管理人員是否決定要Rebuild或著操作其他行為. 當決定要進行Rebuild操作, 按照如下步驟可以使RAID f/w開始操作Rebuild作業: 將Unconfigured Bad的狀態轉成Unconfigured Good; 從控制器掃描Foreign Configuration. 取得Foreign Configuration後, 將它全部清掉. 清掉後的PD將它轉成GSHP或 ..., From the Select operation menu, select Make Unconfigured Good and then press Enter . Use the up arrow key or the down arrow key to select Go and then press Enter . A window is displayed with the message "The operation has been performed successfully,I have an issue with the UCS server that, after swapping the HDD and rebooted, it was fine for a while that everything is in good condition, however, the following day when viewing through CIMC, we have all the HDD showing as unconfigured good, and nothin,It thought all of our previously configured drives were now "unconfigured bad", so I logged into the LSI ... ,... 接上的是一顆全新的硬碟,系統將會自動Rebuild. 2.但是當你是接上原本被判定fail的硬碟時,RAID Card會將此硬碟判定為“Foreign",需要執行以下步驟才能進行rebuild. a. Please launch the RAID utility. b. Right click the HDD marked as “(Foreign) Unconfigured Bad” and select Change to Unconfigured Good. F201110109-, 今天到客戶端更換x3650 M3 主機上的HDD,更換完後發現不會自動rebuild,打開LSI Server RAID Software Tool 看了下,發現新換HDD 狀態是"(Foreign) Unconfigured Good ",對它按右鍵什麼都不能做,跟沒換是一樣的! 於是,我就請教了"股溝大嬸",終於讓我找到了一篇跟我情況一樣的文章。會發生這種情況是 ...

相關軟體 mIRC 資訊

mIRC
mIRC 是一個功能齊全的互聯網中繼聊天客戶端,可用於在多用戶群組會議中或在一對一的私人討論中與其他人在 IRC 網絡上進行交流,分享,播放或與他人合作.It 文件傳輸,多服務器連接,IPv6,SSL 加密,代理支持,UTF- 8 顯示,UPnP,可定制的聲音,口頭消息,托盤通知等功能。消息日誌等等.mIRC 也有一個強大的腳本語言,可以用來自動化 mIRC 和創建應用程序,執行從網絡通信到玩遊戲... mIRC 軟體介紹

unconfigured good 相關參考資料
Foreign Disk Unconfigured Good

It could look like this in the Event Viewer. User-added image. And like this in the MegaRaid Storage Manager User-added image. Go back to the ISIS 5000 management console and follow the following. Us...

http://avid.force.com

How to Replace a Faulty Drive with a Unconfigured Good Status Using...

Changing the status of the new drive from Unconfigured to Online.

https://www.intel.com

IBM QRadar: Disk drive is in "Unconfigured (good)" state after ...

A drive in the QRadar appliance that was replaced, is not automatically rebuilt into the RAID array, and is reported as "Unconfigured (good)".

https://www.ibm.com

Maintain PD Fail History - StoRAID - Google Sites

針對當時的狀況, 視管理人員是否決定要Rebuild或著操作其他行為. 當決定要進行Rebuild操作, 按照如下步驟可以使RAID f/w開始操作Rebuild作業: 將Unconfigured Bad的狀態轉成Unconfigured Good; 從控制器掃描Foreign Configuration. 取得Foreign Configuration後, 將它全部清掉. 清掉後的PD將它轉成...

https://sites.google.com

Rebuilding a RAID 1 array on a management node - IBM

From the Select operation menu, select Make Unconfigured Good and then press Enter . Use the up arrow key or the down arrow key to select Go and then press Enter . A window is displayed with the mess...

https://www.ibm.com

Solved: All HDDs go into unconfigured good afte... - Cisco Support ...

I have an issue with the UCS server that, after swapping the HDD and rebooted, it was fine for a while that everything is in good condition, however, the following day when viewing through CIMC, we ha...

https://supportforums.cisco.co

Using LSI MegaRAID Storage Manager in Windows to recover from ...

It thought all of our previously configured drives were now "unconfigured bad", so I logged into the LSI ...

https://www.youtube.com

假設在MegaRAID 9240-4i利用兩顆HDD做RAID1,有一顆fail後,安裝一顆 ...

... 接上的是一顆全新的硬碟,系統將會自動Rebuild. 2.但是當你是接上原本被判定fail的硬碟時,RAID Card會將此硬碟判定為“Foreign",需要執行以下步驟才能進行rebuild. a. Please launch the RAID utility. b. Right click the HDD marked as “(Foreign) Unconfigured B...

https://tw.answers.acer.com

著了魔: IBM LSI MegaRAID Software, Foreign Drive Problem

今天到客戶端更換x3650 M3 主機上的HDD,更換完後發現不會自動rebuild,打開LSI Server RAID Software Tool 看了下,發現新換HDD 狀態是"(Foreign) Unconfigured Good ",對它按右鍵什麼都不能做,跟沒換是一樣的! 於是,我就請教了"股溝大嬸",終於讓我找到了一篇跟我情況一樣的文章。會發生...

http://fossil720.blogspot.com